Commercial emissions testing for FCC, IC, CE mark, VCCI, CISPR, AS/NZS

Item Specification Comments
Lab Dimensions 36′ long x 20′ wide x 19.5′ high
Lab Door Size 4’ wide x 7’ high
Turntable Diameter 9’ Flush-mounted
Turntable Weight Capacity 4,400 lbs.
Cable length needed for isolation
of EUT support
22’
Loading dock accessible Yes
Ramp accessible Yes
Water and compressed air Upon request Notify CKC prior to testing
Single phase power 120VAC @ 60Hz; 30 Amp
208VAC @ 60Hz; 30 Amp
120VAC @ 50Hz, 25 Amp
230VAC @ 50Hz; 12 Amp
Three phase power 260 VAC @ 50-60Hz; 12 Amp
> 260VAC @ 50-60Hz; 6 Amp
Over 480VAC, ask CKC
Other Power AC Power Supply
0-300VAC @ 45-5000Hz; 15 Amp Max.
DC Power Supply
0-100VDC; 2000 Watts Max.