October 15, 2014

High Intensity Radiated Field (HIRF) facilities at CKC are up, running and booking fast! HIRF testing is a significant expansion of our testing capabilities for the aerospace industry.

Field strength levels of 3,000V/m (Cat. G), per DO-160 Section 20 for mode stirred and mode tuned procedures, can be reached in our copper-lined 10′ x 18′ x 8′ reverberation room. Levels are based on test volume uniform field dimensions of 4′(w) x 10′(l) x 3′(h), or smaller. For some smaller, highly reflective EUTs, test levels of 7,200V/m are possible.

CKC’s HIRF testing system is automated by Nexio’s EMC Automation Control software, creating an industry leading level of efficiency and accuracy.